End-bearing piles
Foundations provide support for structures, transferring their load to layers of soil or rock that have sufficient bearing capacity and suitable settlement characteristics to support them. Very broadly, foundations can be categorised as shallow foundations or deep foundations.
Pile foundations are a type of deep foundation, formed by long, slender, columnar elements typically made from steel or reinforced concrete, or sometimes timber. A foundation is described as 'piled' when its depth is more than three times its breadth.
Pile foundations are principally used to transfer the loads from superstructures, through weak, compressible strata or water onto stronger, more compact, less compressible and stiffer soil or rock at depth. They are typically used for large structures, and in situations where soil may be subject to excessive settlement.
End-bearing piles develop most of their load-bearing capacity at the toe of the pile, bearing on a hard layer of rock or very dense soil and gravel. The pile transmits the load through soft, compressible strata directly onto firm strata. This type of pile therefore acts in the same way as a column.
This is as opposed to friction piles (or floating piles) which develop most of their load-bearing capacity by shear stresses along the sides of the pile, and are suitable where harder layers are too deep to reach economically. The pile transmits the load to the surrounding soil by adhesion or friction between the surface of the pile and the soil. In this case, the whole surface of the pile works to transfer load to the soil.
For more information see: Friction piles.
[edit] Related articles on Designing Buildings
- Bored piles.
- Building foundations.
- Caisson.
- Continuous flight auger piles.
- Driven piles.
- Friction piles.
- Geothermal pile foundations.
- How deep should foundations be?
- Pile foundations.
- Piling equipment.
- Screw pile foundations.
- Sheet piles.
- Socket piles.
- Tension piles.
- Testing pile foundations.
- Types of pile foundation.
Featured articles
Check out some of the best features and news from Designing Buildings as well as key stories from around the web.
Government approach could undermine delivery and regeneration.
World's first mass timber data centre.
The overlooked environmental aspect of data centre development.
Introduction to radon awareness
New technical information sheet published by CIOB.
Updated supplier guide can help electrical contractors engage with NHP.
CIAT confirm the winners of the 2026 architectural technology awards.
Government launches a one stop shop for flood preparedness.
Sir Edwin Lutyens: Britain's greatest architect? Book review.
CIOB publishes free template to help assess and manage risks.
ECA's reflections on Party Conference season
Burnham wants to be confident of winning before asking for a fresh mandate.
New Chief Construction and Scientific Adviser
Sergio Cavalaro, Professor of Infrastructure Systems at Loughborough University.
Building safety levy for England
CIAT publish estimator tool for members.
Water sector faces a growing crisis that could slow the delivery of vital infrastructure.

















Comments
Hi,
Under the below orange dots are piles. The quay has a number of old drawings, but the piles are not described. They have presumably been added in the 1980's but no record exists.
Is there a way to figure out what they are (for example friction or end-bearing piles), and their load bearing strength?
File:Lvens quay reinforcements.jpg
https://www.designingbuildings.co.uk/wiki/File:Älvenäs_quay_reinforcements.jpg ?